Description

The hanging hot aerosol fire extinguishing device is a new type of environmental protection fire protection product with the world's advanced level. It is a new type of high-tech green fire protection product further developed on the basis of the third generation of S-type aerosol.
1、 Product Features:
(1) Green environmental protection products: good cleanliness, atmospheric ozone layer destruction capacity index = 0, global greenhouse effect capacity index = 0.
(2) Stainless steel alloy cylinders will not be corroded, no pressure relief, no leakage, low maintenance.
(3) Passed the fire extinguishing test and certification of the Sky Consumption Institute.
(4) Fire extinguishing without residue: The fire extinguishing agent below 2um is released and is easily dissipated in the air. The amount of particles is less than the amount of dust that naturally falls in a closed computer room within a month.
(5) Lightweight: The volume and weight of other fire extinguishing systems can be reduced by 90%, and it does not occupy the protective area.
(6) Easy to install: no high-pressure vessel or complex distribution network is required, saving space and expensive installation costs.
(7) Convenient design, wide range of adaptation.
(8) The service life is up to 10 years, which is better than other types of fire extinguishing agents. 
2. The hanging hot aerosol fire extinguishing device is suitable for fighting the following fires:
Construction industry: high-rise buildings Transformer rooms for industrial buildings Libraries Archives Reference rooms Underground storage rooms Safes;
Communication industry: telecommunications computer room, communication base station relay station distribution cabinet data processing room remote control room precision equipment distribution cabinet;
Power industry: cable tunnels Cable wells Cable trench narrow space Generator room Insulated oil depot Substation UPS system Within various power plant equipment;
Metallurgical industry: rolling mill equipment room electronic instrument control room electrical basement cable sandwich cable tunnel pressure chamber;
Petrochemical industry: flammable liquid storage area transformer (distribution) generator room cable tunnel cable well distribution cabinet switch cabinet;
Transportation industry: train locomotive Railway source line signal station substation Station signal building Highway signal station Car engine room Turbine room Ship engine room;
Other industries: CNC and other high-priced machines high-priced mobile equipment;
3. The hanging hot aerosol fire extinguishing device cannot be used for the following places and material fires:
Explosion hazard area.
Oxidizing agents such as nitrocellulose.
Potash and other reactive metals
Chemical fires that decompose on their own, such as hydrogen peroxide.
4. Numbering method and model of hanging hot aerosol fire extinguishing device:

1. Numbering method:

2. Basic model:
Model Starting method Chemical weight (g) Protective volume (m³) Release time(s) Dimensions (mm) Equipment weight (kg) Mounting bracket type
QRR0.25GW/S E 250 2.5 10 ø127*140 2.6 L type
E: electric start type; TH: thermal line start type;
5. Working environment requirements
Temperature range: -40 ~ +70 °C
Relative humidity: ≤ 95%RH
Second, the working principle
By the fire alarm controller or gas fire extinguishing control to detect the fire signal, when detected to the fire, the output start signal to the suspension of the hot aerosol fire extinguishing device, the suspension of the hot aerosol fire extinguishing device after receiving the start signal, the internal fire extinguishing agent will be activated, quickly produce nano-type aerosol fire extinguishing agent and spray out, rapid fire extinguishing.
Third, technical parameters
Fire extinguishing time: ≤30s
Nozzle temperature: ≤200 °C (at 5mm of nozzle)
The surface temperature of the housing ≤ 100 °C
Actual fire extinguishing efficiency: ≤ 100g/m3
Feedback signal mode: passive normally open contact

  • Aerosol fire extinguishing device
  • electric start

Production Capacity:

Not informed

Delivery Timeframe:

Not informed

Incoterms:

Not informed

Packaging Details:

Not informed


More about
JIANGXI ZHIYUAN FIRE TECHNOLOGY CO.,LTD

icone de usuario

50-100

Employees

sales icon

2M - 10M

Sales volume (USD)

icone de exportar

10%

% Export sales

2019

Year

Established


Business type
  • Industry / Manufacturer

Keywords
  • Introduction
  • products

Contact and location
  • icone de usuario david liao
  • icone de telefone +86 790 xxxxxxxx
  • map-marker xinyu / jiangxi | China

Make your Request!

Make your Request!

Start conversation
logo-Whatsapp icon-checked-none

Hello 👋!
Can we help you?

Fill in your name and phone number 😁

Start conversation Start conversation